Public simulation


Simulation Icon

EnergyMatching Campi di Bisenzio

Public
Status: Simulated (31-07-2020 09:40:25) Delete

Variable Value
Scalesingle building
Time horizon for the evaluation [years] 30
Supply['centralized heating system', 'centralized cooling system', 'lighting of common spaces']
Number of inhabitants0
Objective of the optimizationmaximum NPV
Annual Discount Rate [%] 1
Net billing premium [€/kWh or auto]0.0
Maximum limit for the initial investment cost [€]none
Price of electricity bought from the grid [€/kWh] 0.18
Price of electricity sold to the grid [€/kWh] 0.05
Module efficiency0.149
Module height (m)0.9
Module width (m)0.35
Cost of battery [€/kWh] 700
Cost of the finished PV system [€/kWp] 1500
Performance ratio of the system at STC 0.8
Linear annual efficiency losses of the PV system [%]0.75
Annual maintenance costs [€/kWp year] 7.5
Linear annual growth of price of electricity bought from the grid [%]1
Linear annual growth of price of electricity sold to the grid [%]0
Linear annual growth of the electric demand [%]1
Variable Value
PV capacity [kWp]0.70
PV area [m²]4.72
Battery capacity [kWh]0.00
Expected Net Present Value [€]1216.87
Self-sufficiency [%] 43.52
Self-consumption [%] 59.63
Annual cumulative production [kWh]767.29
Annual cumulative balance production/consumption0.77
PV system initial cost [€]1056.04
Expected payback time13 years 11 months 0 days
Expected LCOE considering self-consumed electricity [€/kWh]0.11
Expected LCOE considering the produced electricity [€/kWh]0.08
Specific emission of self-consumed electricity [kg CO2-eq/MWh]146.57
Specific emissions of the produced electricity [kg CO2-eq/MWh]102.55
File Download
Optimization reportem_report.pdf
Area available for PVPV_areas.obj
Area suggested for PVPV_layer.obj
Contextcontext.obj
Suggested PV configuration
Weather fileepwfile.epw
PV Production ProfileProductionProfile.csv
Electric Demand ProfileConsumptionProfile.csv